2ml ND8 Screw Vial

Designed for use with matching 8 mm screw caps and septa, the ND8 screw vial is a practical option for laboratories that need stable sealing, easy handling, and broad autosampler compatibility. Agilent and Thermo Fisher both treat 8-425 screw-top vials as a standard vial family in their compatibility references.

Additional information

Brand

Mastelf

Material

Type 33, 51 and 70

Bottom Type

Flat Bottom

Writing Patch

Available

Color

Amber and Clear

Size

12x32mm

Silanized

No

Packing

Pakkaging in pp tray and plastic film covered

Volume

2mL

Autosampler compatibility

HPLC and GC

Storage Temperature

RT

Additional(s)

ND8 Neck Screw

The 2mL ND8 Screw Vial is a standard autosampler vial designed for chromatography sample storage and routine laboratory analysis. Featuring an ND8 / 8-425 screw neck and a standard 32 mm vial height, it is widely used in HPLC, GC, and other analytical workflows that require secure sealing and reliable sample handling. Official product data from Agilent and Shimadzu shows this vial format as a standard 2 mL class / 1.5 mL usable-volume class vial in the 12 × 32 mm / 32 × 11.6 mm format.

Designed for use with matching 8 mm screw caps and septa, the ND8 screw vial is a practical option for laboratories that need stable sealing, easy handling, and broad autosampler compatibility. Agilent and Thermo Fisher both treat 8-425 screw-top vials as a standard vial family in their compatibility references.

Key Features

  • Standard 2mL class autosampler vial
  • ND8 / 8-425 screw neck design
  • Common vial size: 12 × 32 mm or 32 × 11.6 mm
  • Suitable for HPLC, GC, and routine autosampler analysis
  • Compatible with matching ND8 screw caps and septa
  • Available in clear and amber glass
  • Reliable sealing for routine laboratory use
  • Suitable for a wide range of standard analytical platforms

Specifications

  • Product Name: 2mL ND8 Screw Vial
  • Neck Type: ND8 / 8-425 Screw Thread
  • Capacity: 2mL nominal
  • Usable Volume: typically about 1.5mL depending on design
  • Dimensions: 12 × 32 mm or 32 × 11.6 mm
  • Material: Glass
  • Color Options: Clear / Amber
  • Closure Type: Screw Cap
  • Recommended Use: HPLC, GC, autosampler sample analysis, routine laboratory testing

Compatible Autosamplers

The 2mL ND8 Screw Vial is commonly compatible with many standard autosampler platforms designed for 8-425 screw thread vials. Thermo Fisher’s official compatibility chart lists a broad range of supported instrument families for 8-425 standard opening screw thread vials, and Agilent’s own compatibility page confirms that this vial family is widely used across multiple instrument brands.

Common Compatible Instrument Brands

  • Agilent
  • Shimadzu
  • Waters
  • Thermo Scientific
  • Dionex
  • PerkinElmer
  • CTC / LEAP
  • Gilson
  • Jasco
  • Knauer
  • Hitachi / VWR
  • Beckman
  • Spark Holland

Typical Compatible Autosampler Platforms

Agilent

  • 1100 / 1200 / 1290 Infinity
  • 1260 Infinity
  • 7673A
  • 7683A
    These Agilent families appear in Thermo Fisher’s official vial compatibility chart under vial categories that include 8-425 screw thread vials.

Waters

  • 717 / 717 Plus
  • Alliance series
  • 2690 / 2695
  • 2790 / 2795
  • 2707 / 2767 / 2777
    These Waters systems are included in Thermo Fisher’s compatibility chart for standard autosampler vial categories that cover 8-425 screw thread formats.

Thermo Scientific / Dionex

  • TriPlus series
  • Dionex UltiMate WPS-3000
  • Other autosamplers supporting 8-425 standard-opening screw vials
    Thermo Fisher’s own chart and vial references treat 8-425 screw thread vials as a standard offering for multiple Thermo autosampler families.

PerkinElmer

  • Series 200 autosamplers
  • AS-100 / AS-100B
  • AS-2000 / AS-2000B
  • AS-300 / AS-8300
    These are also listed in Thermo Fisher’s compatibility chart for standard vial families that include 8-425 screw vials.

Shimadzu and Other Common Brands

Shimadzu officially sells ND8 screw vials in 32 × 11.6 mm format, which supports the positioning of ND8 as a standard vial type in Shimadzu workflows. Other brands commonly associated with this vial format in compatibility references include CTC/LEAP, Gilson, Jasco, Knauer, Hitachi/VWR, Beckman, and Spark Holland.

Compatibility Note

Compatibility may vary depending on the autosampler tray, vial plate, rack holder, needle geometry, and instrument configuration. Thermo Fisher’s official chart notes that some autosamplers may require optional vial trays or configuration changes to use all listed vial types. For bulk orders, it is best to confirm the required vial dimensions and tray format with your instrument model.

Available Options

The 2mL ND8 Screw Vial is commonly available in:

  • Clear glass
  • Amber glass
  • With or without write-on patch

Shimadzu’s official ND8 listings include clear and amber versions in the same general format, showing how this vial style is commonly offered in multiple configurations.

Applications

The 2mL ND8 Screw Vial is suitable for:

  • HPLC analysis
  • GC analysis
  • Autosampler sample injection
  • Routine laboratory testing
  • Pharmaceutical analysis
  • Environmental analysis
  • Food and beverage testing
  • Chemical analysis
  • Research laboratories
    This application range is consistent with how Agilent, Thermo Fisher, and other chromatography suppliers position 8-425 screw-top autosampler vials.

Clear vs. Amber

Clear ND8 Screw Vials are suitable for routine applications where sample visibility is important.
Amber ND8 Screw Vials are recommended for light-sensitive samples that require protection from UV or visible light exposure during storage and analysis. Both Agilent and Shimadzu offer amber ND8 / 8-425 vial variants in this same standard format.

Why Choose ND8 Screw Vials?

ND8 screw vials are widely used because they combine a standard autosampler format with practical screw-cap operation and broad instrument compatibility. Official compatibility references from Agilent and Thermo Fisher show that 8-425 screw thread vials remain a mainstream format for many HPLC and GC sample handling systems.

Precautions

  • Please use compatible ND8 / 8-425 screw caps and septa.
  • Confirm vial compatibility with your autosampler tray and rack before routine use.
  • Choose amber vials for light-sensitive samples.
  • Store vials in a clean, dust-free environment before use.
  • For critical methods, verify vial suitability during method validation.
    These precautions are consistent with official compatibility guidance indicating that tray and platform details can affect actual fit.

FAQ

Q1: What is a 2mL ND8 Screw Vial used for?

It is commonly used for HPLC, GC, autosampler analysis, and routine laboratory sample handling.

Q2: What does ND8 mean?

ND8 refers to the 8 mm screw neck / 8-425 thread finish used with compatible caps and septa.

Q3: Which autosamplers are compatible with ND8 screw vials?

Common compatible platforms include many autosamplers from Agilent, Shimadzu, Waters, Thermo Scientific, Dionex, PerkinElmer, CTC/LEAP, Gilson, Jasco, Knauer, Hitachi/VWR, Beckman, and Spark Holland, depending on tray format and configuration.

Q4: Is this vial suitable for both HPLC and GC?

Yes. ND8 / 8-425 screw vials are commonly used across both HPLC and GC workflows.

Q5: What is the typical vial size?

The common standard is 12 × 32 mm or about 32 × 11.6 mm, depending on how the supplier expresses the dimensions.

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@mastelf.com”